

Specification Sheets (pdf files) |
|||||
| Residential | Commercial | Radiant | |||
| RA-32 | RA-18 | CA-32 | CA-14 | SH-28 | SH-12-208 |
| RA-28 | RA-16 | CA-28 | CA-12-208 | SH-28-208 | SH-11 |
| RA-28-208 | RA-14 | CA-28-208 | CA-11 | SH-24-208 | SH-9 |
| RA-24-208 | RA-14-208 | CA-24-208 | CA-9 | SH-22 | SH-7 |
| RA-22 | CA-22 | CA-7 | SH-18 | SH-5 | |
| CA-18 | CA-5 | SH-14 | |||
| CA-16 | CA-14-208 | SH-14-208 | |||

Where To Buy-Distributors |
|||
| Exclusive Internet Distributors | Barnett | Wisconsin, North Dakota & Iowa |
Radiant Heating |
| Tankless-water-heaters.com | Moore Supply | Johnstone Supply | Heatmyfloors.com |
| National/Regional | Nebraska and Iowa | Dallas Area | Terratherm |
| Coburns | Charleston, Inc | H20 Supply | Radiant and More |
| Morrison Supply | South Dakota | Florida | Solar Heating |
| Winnelson | Johnstone Supply | Broedell | Solardirect |
| Ferguson Enterprises | Holt Supply | The Solarstore | |
| The Stockmarket | |||

Manufacturer's Representatives: |
|||||
| Upper Midwest Franz Burris 612-619-7406 |
Alabama, Florida Panhandle Tim Morales & Associates 251-602-8333 tim@timmorales.com |
North & West Texas Bill Hudson EVP Sales (C)504-382-2151 |
Utah & Colorado Jensen Sales & Marketing 801-746-4476 |
Southern California ADEL Sales Adelsca@gmail.com |
|
| Florida & Georgia Marsh & Moore 800-821-9936 904-827-8788 mminfo@marshmoore.com |
Louisiana & Mississippi Billingsley and Associates, Inc. 504-602-8100 |
South Texas MRK Sales 713-721-8722 steve@mrk-sales.com |
Oregon/Washington Five Star Marketing 360-897-2870 |
West Virginia Thompson Mechanical Sales 304-759-2201 thompsonmech@aol.com |
|
| Indiana RCI Sales & Marketing, Inc. 317-899-7474 |
Sarah Thompson Inside Sales 888.296.9293 |
Other Locations / Info sales@seisco.com 888-296-9293 |
Memphis/Western Tennessee Central Sales Co 901-278-2251 regina@cscmemphis.com |
||

Quick Service Guides |
| Quick Service Guide(Includes All Trouble Codes and Testing Information) |
| Installation and Service Manual(Large Detailed Manual With Photos) |
| Circuit Board Replacement Instructions |
| Warranty Summary |
| Parts Listing |

Warranty Information, Literature & Manuals |
||
|
Warranty |
Literature |
Manuals |
|
includes all trouble codes and testing information) |
Tri-Fold Consumer Brochure Interlock Relay Option |
Water Heater Owner’s Manual |
|
Installation and Service Manual (Large detailed manual with photos) |
||
|
Circuit Board Replacement Instructions |
28-32KW Optional Wiring Diagram |
|
TANKLESS MODEL SELECTION CRITERIA
Below is a list of the basic information that is needed for selecting the proper Seisco model:
- Peak flow rate in gallons per minute (GPM).
- Inlet water temperature or cold water temperature.
- Electrical capacity (amps) and the service voltage (VAC).
- Desired output temperature or hot water temperature.
Additional information may be necessary for space heating applications, such as the following:
- Heat loss rate (BTU/hr) of the home or building.
- Flow rate of the circulating pump in gallons per minute (GPM).
Peak Flow Rate:
Below are typical flow rates for new residential construction. There may be exceptions, such as with new designer type fixtures and faucets. For instance, large custom body spa showers, whirl pool and Jacuzzi tubs may have faucets with flow rates ranging from 7 gpm to 14 gpm. However, a combination of multiple Seisco heaters (plumbed in a parallel configuration) can be installed to match these higher flow rates. The same peak design approach would be necessary for the anticipated life style of multiple flow rates occurring at the same time. Otherwise, use the table below and match the Seisco according to the peak flow and associated temperature rise of a single tub or shower. Also, refer to the Product Specification Tables in the "Description & Specifications" section of the Seisco Product Manual for the flow ratings of each Seisco Model.
Typical Flow Rates in Gallons per Minute (gpm)
| Fixture Type | Lavatory | Bathtub | Shower | Kitchen Sink | Pantry Sink | Laundry Sink | Dish-Washer |
| Flow Rates | 0.8 — 1.5 | 2.0 — 4.0 | 1.5 — 3.0 | 1.0 — 1.5 | 1.5 — 2.5 | 2.5 — 3.0 | 2.0 — 3.0 |
Measuring flow rates at a faucet can be done by simply using a common one-gallon bucket or a similar container of known liquid capacity. The approximate flow rate can be determined by simply turning on the faucet in question to full flow, and timing how long it takes to fill the one gallon bucket. If it takes 20 seconds to fill the one gallon bucket, then the flow rate is 3 gallons per minute or 3 gpm. If it takes 15 seconds to fill the bucket, then the flow rate is 4 gpm. Simply divide 60 seconds (which is one minute) by the recorded time to fill the bucket to arrive at the flow rate.
Inlet Temperatures:
Measuring the inlet temperature can be determined with a common cooking or baking thermometer. Simply turn on the cold water (not the hot) and place the thermometer into the flow. For best results, let the water run for approximately one to two minutes before taking the reading. This allows purging of any ambient temperature water sitting in the lines. It is important to know the inlet water temperature so that the temperature rise can be determined. The temperature rise and associated flow rating of the faucets are necessary for the proper model selection.
Inlet water temperatures can vary depending on geographical location, season of the year and the type of water system. For instance, Southern Georgia and Florida have inlet water temperatures typically between 60 and 70 degrees F. Mountainous areas, such as the Rockies may have water temperatures as low as 40 degrees F. In the middle and northern sections of the U.S., temperatures generally range from 45 to 55 degrees F. Most well water systems (except in mountainous areas) generally remain constant at 50 to 55 degrees year round.
Electrical Capacity:
Most electric homes today have 200 amp electric services. This has become the standard over the past 10 years or so in new home construction. However, homes that utilize gas for space heating, water heating and cooking may have 100 or 150 amp electric service. It is important to know whether the electrical capacity of the home or building is sufficient for the Seisco heater. In most cases, an all electric home of 3000 square feet or less with a 200 amp whole-house electric service will have the electrical capacity for one Seisco RA-28. The RA-28 is sufficient to provide all the hot water for a home of this size containing 2 _ or 3 baths with standard flow rate faucets.
It will be necessary however, to have a qualified electrician calculate the electrical loads in the home or building with the load of the selected Seisco model(s). The load calculations should be done according to the National Electric Code (NEC), 220-30 and 220-31, Optional Calculation. Refer to the "Electrical Service Requirements & Sample Calculations" section of the Seisco Product Manual for how the NEC rules apply to the Seisco.
- Tankless Water Heaters
- What Is Seisco
- Why Go Tankless
- Cost Of A Tankless Water Heater
- Where To Buy a Seisco
- Other Products
- Water Heater
- Boilers
- Point Of Use
- New Highlights
- Press Release
- Upcoming Events
- NexGen Green Home
- EHVA Builders Show
