Product
Specifications Table
Commercial 208 Volt (AC) Operation,
240 VAC Rating
Commercial and industrial locations are often served by
208 V three-phase electrical services. Where 240-V rated SEISCO heaters
are used at 208 V, their available wattage, and therefore their temperature
rise, are de-rated by 25%. The table below shows which ratings are affected.
Other specifications are the same as for 240 V operation.
SEISCO®
Electric Fluid Heating System
BACK
TO Tankless Water Heater Product Guide
[ Four Chamber
Models ]
|
MODEL
|
RA-28
|
RA-22
|
RA-18
|
|
kW
|
21
|
16.5
|
13.5
|
|
Elements
|
7000 watts ´ 4
|
5500 watts ´ 4
|
4500 watts ´ 4
|
|
Btu/hr
|
71670
|
56310
|
46070
|
|
kg-cal/min
|
300
|
236
|
194
|
|
TEMPERATURE RISE
|
|
|
71 °F @ 2.0 GPM
57 °F @ 2.5 GPM
48 °F @ 3.0 GPM
36 °F @ 4.0 GPM
|
56 °F @ 2.0 GPM
45 °F @ 2.5 GPM
37 °F @ 3.0 GPM
28 °F @ 4.0 GPM
|
45 °F @ 2.0 GPM
36 °F @ 2.5 GPM
30 °F @ 3.0 GPM
22 °F @ 4.0 GPM
|
|
37 °C @ 8 L/min
30 °C @ 10 L/min
25 °C @ 12 L/min
19 °C @ 16 L/min
|
30 °C @ 8 L/min
24 °C @ 10 L/min
20 °C @ 12 L/min
15 °C @ 16 L/min
|
24 °C @ 8 L/min
19 °C @ 10 L/min
15 °C @ 12 L/min
12 °C @ 16 L/min
|
|
ELECTRICAL
|
|
V
|
208
|
208
|
208
|
|
A (max)
|
101
|
79
|
65
|
|
Hz
|
50 / 60
|
50 / 60
|
50 / 60
|
|
Circuits
|
30A x 4
|
50A x 2
|
40A x 2
|
|
|
|