COMPONENT TESTING TABLE
Power Lugs
Temperature Sensors
High
Temperature Limit Switches
Heating Elements
Water / Level Detectors
Moisture Detector
Component
Testing Table
SEISCO Tankless Water Heaters
|
Component
|
Type of Test
|
Power Status
On /
Off
|
Expected Results
|
|
Incoming
Power Lugs (Control Board)
BACK TO TOP?
|
Verify Power to Lugs
Voltage
|
On
|
Phase Check Measurements
(Individual Circuit)
L1 to L2 208 240 Volts
(AC)
L1 to Ground 110 120
Volts (AC)
L2 to Ground 110 120
Volts (AC)
Sequence Check Measurements
(Circuit to Circuit)
L1 to L1 0 Volts (AC)
L2 to L2 0 Volts (AC)
|
|
Temperature
sensors
(Chamber)
BACK TO TOP?
|
Continuity Ohms
|
Off
|
Ohm readings should be taken
after the heater has been cooled down so that the temperature in
the chamber is uniform. All temperature sensors should read within
25 ohms of each other.
For EXAMPLE, on an RA-28 with
a 50 deg. F inlet water temp., the expected temperature sensor readings
may read as follows:
THIN ~ 358 Ohms
TH1 ~ 348 Ohms
TH2 ~ 353 Ohms
TH3 ~ 346 Ohms
TH4 ~ 351 Ohms
Most temperature sensor readings
will fall within 200 to 400 ohms, provided the heater is cooled
down first.
|
|
High
Temperature Limit Switch
(Chamber)
|
Continuity
Ohms
|
Off
|
Should read 0- ohms
If test shows open, press the
reset button and retest
|
|
Heating Element
(Chamber)
BACK TO TOP?
|
Continuity
Ohms
|
Off
|
Read across screws at the Red
& Black wires. Ohm readings should fall into the following range
(also allow +/- 1% tolerance):
4500W ~ 12.5 to 13.5 Ohms
5500W ~ 9.5 to 10.5 Ohms
7000W ~ 7.5 to 8.5 Ohms
|
|
|
|
|
|
|
Component
|
Type of Test
|
Power Status
On /
Off
|
Expected Results
|
|
Heating
Element
(Control Board)
BACK TO TOP?
|
Full Flow Test
Amps
|
On
On
|
With the power on to all circuits,
and water running at full flow at a sink or tub faucet, measure
the amps on each Red or Black element wire, going from the control
board to the element. Maximum expected readings as follows:
RA-28 ~ 29 amps ea.
RA-22 ~ 23 amps ea.
RA-18 ~ 19 amps ea.
RA-14 ~ 29 amps ea.
RA-11 ~ 23 amps ea.
RA-9 ~ 19 amps ea.
Allow for +/-10% tolerance in
readings due to meter error.
|
|
Heating Element
(Control Board)
|
Modulation Test Amps
|
On
|
With power on and water at _
(half) flow at the sink faucet, check amps at each element. Power
should modulate and amp readings may fluctuate, but all should read
approximately the same amps.
|
|
Level Detector
Switch
(Chamber)
|
Ohms
|
Off
|
Each contact should read -0-
ohms to ground.
|
|
Moisture
Detector Switch
(Control Board)
|
Ohms
|
Off
|
Should normally read open. If
reading continuity, check for water leaks or water on the switch
pad (mounted on the bottom of the base pan). Correct the leak or
dry the switch and retest.
|